M/s. Gulf Analytical Supplies FZE have an established presence of nearly a decade in the middle east market and have a dominant presence in the field of separation science comprising mainly of chromatography with more than thousand columns supplied in the Middle East.  With the help of application support and technical support from our principals, we are the pioneers in the field of column chromatography.
 
 
 

     SGE Analytical Science
     
      Syringes and Accessories

      
eVol
   
     GC Capillary columns

      GC Accessories

      GC Supplies

      HPLC Columns

      Tubing

      Knauer Germany

      Dosing Pumps

      Knauer LC Columns Overview

      
Eurospher I
   
     Euroshper II

      Blue Orchid

      Bluespher

      BlueShell

      Eurocel

      Eurokat 

      Thermo Fisher Scientific

      GC based Petroleum Analyzers &             Spectronic 200 Visible             Spectrophotometer

      Pipettes

      Visible Spectrophotometer

      Cool Spectro 100

       Cool pH - Conductivity Meter Dual

      pH - Conductivity Meter            

Products / SGE Analytical Science / Eurokat

Eurokat
Stability
Eurokat polymer columns are extremely stable over the whole pH range. This is one striking advantage compared with silica-based phases which have a limited lifetime at pH extremes, especially in the higher pH range. Most importantly, Eurokat phases show extraordinary column lifetime stability and are not affected by aqueous solvents.
product
Choice of chromatographic conditions
Outstanding separation results are achieved isocratically with fresh double-distilled water for Pb or Ca, or Ag type Eurokat columns, while Eurokat H columns perform best when using inorganic acids. Such aqueous eluents produce no harmful waste as with organic solvents such as acetonitrile which necessitate expensive disposal.
product
Choice of chromatographic conditions
The Eurokat stationary phase is designed to be applicable to a wide range of diverse chromatographic conditions. All Eurokat columns can be used at temperatures up to 90 C under diverse pH conditions (e.g. using 0.001– 0.1 N H2SO4). For example, the best separation of sugars can be achieved using an acidic aqueous mobile phase at a temperature between 60 to 90 C. To extend separation performance, it is possible to connect up to three columns of Eurokat in series.
KNAUER column hardware
We design and manufacture HPLC column hardware under strict quality control. A specially treated inner surface ensures consistent column packing and high column stability. Eurokat columns are available in lengths of 30, 120, and 300 mm. The 30 mm version is recommended as a guard column.
product
< 1 2 3 4 >
© 2012 Gulf Analytical Supplies FZE