M/s. Gulf Analytical Supplies FZE have an established presence of nearly a decade in the middle east market and have a dominant presence in the field of separation science comprising mainly of chromatography with more than thousand columns supplied in the Middle East.  With the help of application support and technical support from our principals, we are the pioneers in the field of column chromatography.
 
 
 

     SGE Analytical Science
     
      Syringes and Accessories

      
eVol
   
     GC Capillary columns

      GC Accessories

      GC Supplies

      HPLC Columns

      Tubing

      Knauer Germany

      Dosing Pumps

      Knauer LC Columns Overview

      
Eurospher I
   
     Euroshper II

      Blue Orchid

      Bluespher

      BlueShell

      Eurocel

      Eurokat 

      Thermo Fisher Scientific

      GC based Petroleum Analyzers &             Spectronic 200 Visible             Spectrophotometer

      Pipettes

      Visible Spectrophotometer

      Cool Spectro 100

       Cool pH - Conductivity Meter Dual

      pH - Conductivity Meter            

Products / SGE Analytical Science / Syringes And Accessories

Syringes and Accessories
Syringe Cleaning Steps:

1. Rinse thoroughly with suitable solvent.
2. Rinse with distilled water.
3. Flush with acetone.
4. Remove plunger and wipe with tissue.
5. Refit plunger and flush with acetone.
6. Allow syringe to dry.

Cleaning Steps for NanoVolume syringes can be found in the manual supplied with the syringe.
SGE Syringe Temperature Specifications
Heating will remove semi-volatile material from the syringe. Before heating or autoclaving remove the plunger.
• Fixed Needle and Fixed Luer Syringes can be heated in an oven to 70 C.
• Removable Needle and Removable Luer Syringes can be heated in an oven to 120 C.
• NanoVolume Syringes can be heated in an oven to 70 C.
Rapid changes in temperature can lead to splitting of the glass barrel. Ensure heating and cooling of a syringe is a gradual process.
Plunger Care
Metal Plungers for Standard Syringes
• Never force the plunger.
• Do not pump the plunger when the needle is blocked as the high pressure generated could crack the   barrel.
• Replacement metal plungers are not available. Plungers are individually fitted to the barrels to achieve   a perfect seal. This means that plungers are not interchangeable.
• Avoid unnecessary movement of plungers when the syringe is dry.
Metal Plungers for NanoVolume Syringes
• Always loosen needle cover nut before removing or inserting plunger.
• Wipe plunger with a lint-free tissue before replacing into the syringe. For more
 


 
< 1 2 3 4 5 6 7 8 >